5
2.1.2 Uncover control elements
4. Push the aluminium speaker grille down (see
figure 4).
2.1.3 Wiring and wall mounting
5. Use the wall mounting
template at the end of the
manual to mark the
position for the screw
holes and cable
connection on the
mounting surface. Drill the
holes.
6. Feed the cable (analogue
line, power supply, lock
see figure - 6) through the
cable hole.
Fix the panel to the wall
using the screws and
rawlplugs supplied.
Note: Some materials such as metal and wood may require special
screw types.
To power the unit for voice, connect the telephone wires into the terminal
(on the right side). Using either a standard analogue phone line or an
analogue extension on a PBX.
For the external power supply, connect to the terminal "12V" external
power supply AC min. 10V / max. 15V or DC min. 12V / max. 18V.
The energy consumption of a connected electrical (magnetic) lock (0,5A
1,0A) determines the load on the power supply. If you activate the heating
feature the PCB current will climb to about 150mA. We recommend
power supply AC 12V/1A.