Seite 2 - Safety Notes

10 041-135-B0-001 Rev. A (07/2013)2.0 Operation, continued2.2 Fuel LevelGasoline is extremely ammable and can be explosive. Refuel in a well-ventil

Seite 3 - 36VDC Portable Generator

11041-135-B0-001 Rev. A (07/2013)2.0 Operation, continued2.3 Air CleanerNever run the engine without the air cleaner element in place. Rapid engine

Seite 4 - Table of Contents

12 041-135-B0-001 Rev. A (07/2013)2.4 Power System Connections2.4.1 Y-Style ConnectionFig. 2-4, Y-Style Connection213F us eALM/RDYRSTFLASH = MIN ALM

Seite 5 - Figures & Tables

13041-135-B0-001 Rev. A (07/2013)Fig. 2-5, Ring Lug Style Connection2.4 Power System Connections, continued2.4.2 Ring Lug Style Connection2.0 Opera

Seite 6

14 041-135-B0-001 Rev. A (07/2013)2.4 Power System Connections, continued2.4.3 Alligator Clamp Style Connection2.0 Operation, continuedREDBLACK213F

Seite 7 - 1.0 Introduction

15041-135-B0-001 Rev. A (07/2013)2.5 Start-UpBefore starting the engine, verify the output circuit breaker is in the OFF position.Procedure:1. Connec

Seite 8

16 041-135-B0-001 Rev. A (07/2013)2.0 Operation, continued2.6 Operation at High AltitudeThe standard carburetor air-fuel mixture will be excessively

Seite 9 - 2.0 Operation

17041-135-B0-001 Rev. A (07/2013)2.0 Operation, continued2.9 Output, Alarm and Oil LEDsBefore connecting or reconnecting a power supply to the gener

Seite 10 - CAUTION!

18 041-135-B0-001 Rev. A (07/2013)3.0 ServicingThe maintenance schedule (Section 3.2, Maintenance Schedule) maintains the generator in peak operating

Seite 11 - 2.3 Air Cleaner

19041-135-B0-001 Rev. A (07/2013)3.0 Servicing, continued3.1 Emission Control System, continuedReplacement Parts and AccessoriesThe parts making up

Seite 12 - 2.4.1 Y-Style Connection

Safety NotesReview the drawings and illustrations contained in this manual before proceeding. If there are any questions regarding the safe installati

Seite 13

20 041-135-B0-001 Rev. A (07/2013)3.2 Maintenance ScheduleItemMaintenance ProcedureRegular Service period. Perform at every indicated month or operat

Seite 14

21041-135-B0-001 Rev. A (07/2013)3.0 Servicing, continued3.3 Changing OilEngine oil is HOT! Avoid contact with skin and clothing.WARNING! BURN HAZAR

Seite 15 - 36V DC GENERATOR

22 041-135-B0-001 Rev. A (07/2013)3.4 Air Cleaner ServiceDo not use gasoline or low ash point solvents for cleaning. They are ammable and explosive

Seite 16 - Recommended Oil

23041-135-B0-001 Rev. A (07/2013)3.0 Servicing, continued3.5 Spark Plug MaintenanceTo ensure proper engine operation, the spark plug must be in good

Seite 17

24 041-135-B0-001 Rev. A (07/2013)Fig. 3-5, Accessing the Spark ArrestorSpark ArrestorM6 ScrewsMufer GrillM4 Screws3.0 Servicing, continued3.6 Spar

Seite 18 - 3.0 Servicing

25041-135-B0-001 Rev. A (07/2013)4.0 Transport and Storage Instructions4.1 Transporting the GeneratorWhen transporting the generator, it should alwa

Seite 19 - EMISSION CONTROL INFORMATION

26 041-135-B0-001 Rev. A (07/2013)Fig. 4-1, Starter Grip4.0 Transport and Storage Instructions, continued4.4 Long Term StorageGasoline is extremely

Seite 20 - 3.2 Maintenance Schedule

27041-135-B0-001 Rev. A (07/2013)Fig. 5-1, Replace Spark PlugSpark Plug Cap5.0 TroubleshootingDescription of Problem Corrective ActionEngine will not

Seite 21 - WARNING! BURN HAZARD

28 041-135-B0-001 Rev. A (07/2013)6.0 SpecicationsDCX2000 Portable Generator SpecicationsGeneratorModel DCX2000-36Rated Voltage (VDC) 39.5Rated Cur

Seite 22 - WARNING! FIRE HAZARD

29041-135-B0-001 Rev. A (07/2013)7.0 Warranty Information7.1 California Emissions Control Warranty StatementWarranty Rights and ObligationsThe Calif

Seite 23 - 3.5 Spark Plug Maintenance

3041-135-B0-001 Rev. A (07/2013)AlphaGen DCX200036VDC Portable Generator Operation Manual041-135-B0-001, Rev. AEffective Date: July 2013Copyright 2013

Seite 24

30 041-135-B0-001 Rev. A (07/2013)7.0 Warranty Information, continued7.2 Emission Control System WarrantyThe generator engine complies with U.S. Env

Seite 25

Visit us at www.alpha.comAlpha Technologies Inc.3767 Alpha WayBellingham, WA 98226 United StatesTel: +1 360 647 2360Fax: +1 360 671 4936Alpha Technolo

Seite 26 - 4.4 Long Term Storage

4 041-135-B0-001 Rev. A (07/2013)Table of ContentsDCX2000 Portable Generator Safety Notes ...

Seite 27 - 5.0 Troubleshooting

5041-135-B0-001 Rev. A (07/2013)Figures & TablesFig. 1-1, DCX2000 Generator Components ...

Seite 28 - 6.0 Specications

6 041-135-B0-001 Rev. A (07/2013)DCX2000 Portable Generator Safety NotesThe manufacturer cannot anticipate every circumstance that may involve a hazar

Seite 29 - 7.0 Warranty Information

7041-135-B0-001 Rev. A (07/2013)1.0 IntroductionThe Alphagen DCX2000 portable DC generator supplies DC voltage to a power supply battery bus when comm

Seite 30

8 041-135-B0-001 Rev. A (07/2013)1.0 Introduction, continued1.1 DCX2000 Generator Components, continuedThe engine serial number is stamped on the en

Seite 31 - Visit us at www.alpha.com

9041-135-B0-001 Rev. A (07/2013)2.1 Oil LevelPower OFF the generator engine and place on a level surface before servicing.WARNING! ELECTRICAL HAZARD•