Status Monitoring
AlphaNet EDH-A2
Specifications XP-EDH-A2
Power Supplies Supported:
XM2-HP, XM2 (requires USM2 or USM2.5 card)
XM (requires APM/USM), AM (requires RPM card)
Lectro ZTT, ZTT+ and CPR
DOCSIS Compatibility: DOCSIS 1.1, 2.0
Monitoring Protocol: SNMPv1
Devices Monitored: Power supply, batteries
1
Notes:
1
Reported as per ANSI/SCTE 25-3 2002 (HMS-022)
RF Transmit/Receive
Tx Frequency Range: 5 to 42MHz
Output Power: 8 to 55dBmV
Channel Bandwidth: 6MHz
Receive Center
Freq Range:
91 to 857MHz (Standard, HRC, IRC channels)
Input Level: -15 to 15dBmV
Monitored Parameters
Power Supply Data
Model:
XM2-HP/
XM2
XM AM
ZTT
Series
CPR
Major Alarm:
Minor Alarm:
Input Line Voltage Present:
1
1
1
Output Voltage:
1
Battery Voltage:
Output Current:
1
Standby/AC Line Fail:
Equipment/Test Fail: - -
Enclosure Door Status:
Remote Test Control:
Notes:
1
Requires optional cable assembly
Number of Battery Strings: Up to two 36V or 48V strings
Battery Data:
Individual battery voltages
Battery compartment temperature
Hardware
Dimensions
H x W x D (in/mm):
1.3 x 8.6 x 5.2 / 33 x 218 x 132
RF Cable Interface: F-connector, female, 75Ohm
Local/Craft Interface: USB
Environment
Operating Temperature: -40 to 65°C / -40 to 149°F
Humidity: 10 to 90% non-condensing
Emissions:
EN55022 Class A and FCC Part 15 Class A
(Installed in power supply enclosure system)
Immunity:
Surge Test per Specification (IEEE C62.41-1991)
ESD Protection: ±8kV air discharge, ±6kV
contact discharge as per (IEC 61000-4-2)
Management
NMS/EMS: Standard SNMP Management Tools
HMS MIBs:
In addition to the standard DOCSIS MIBs, the
transponder supports the following HMS MIBs:
• SCTE 25-3 (HMS-022): - Interface
• SCTE 36 (HMS-050): - Root
• MIB SCTE 37 (HMS-072): - Tree
• MIB SCTE 38-1 (HMS-026): - Property
• MIB SCTE 38-2 (HMS-023): - Alarm MIB
• SCTE 38-3 (HMS-024): - Common
• MIB SCTE 38-4 (HMS-027): - Power Supply
• MIB SCTE 38-7 (HMS-050): - TIB MIB
> Add DOCSIS Status Monitoring capability
to existing power supplies
> Supports standard networking interfaces including
SNMP, Web access and ANSI/SCTE MIBs
> Multiple power supply models supported
> Embedded Web server for remote diagnostics
AlphaNet
EDH-A2
External DOCSIS
®
Transponder
AlphaNet EDH-A2
Seitenansicht 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 55 56

Kommentare zu diesen Handbüchern

Keine Kommentare