8GENERATOR SAFETYRefuel With CareGasoline is extremely flammable, and gasoline vapor can explode.Allow the engine to cool if the generator has been in

Seite 3 - INTRODUCTION

9GENERATOR SAFETYSAFETY LABEL LOCATIONSThese labels warn you of potential hazards that can cause seriousinjury. Read them carefully. If a label comes

Seite 4 - IMPORTANT SAFETY INFORMATION

10GENERATOR SAFETY07/06/26 12:59:21 31ZS9700_011

Seite 5 - CONTENTS

11COMPONENT & CONTROL LOCATIONSCONTROLS & FEATURESENGINE SWITCHCHOKE KNOBFUEL VALVE LEVEROUTPUTINDICATOROVERLOADINDICATOROUTPUT SWITCHGROUNDTE

Seite 6

12CONTROL & FEATURESOIL FILLER CAP/DIPSTICKMAINTENANCE COVEROIL MAINTENANCECOVEROIL DRAINPLUGMUFFLERFRONT HANDLEDC VOLTAGESELECTOR SWITCHAIR CLEAN

Seite 7

13CONTROL & FEATURESCONTROLSDC Voltage Selector SwitchFuel Valve LeverOOFFFFOONNDCVOLTAGE SELECTOR SWITCHFUEL VALVE LEVERMAINTENANCE COVERThe DC v

Seite 8

−−14CONTROL & FEATURESChoke KnobEngine SwitchCHOKE KNOBOOPPEENNOOFFFFOONNCCLLOOSSEEDDENGINE SWITCHENGINE SWITCH KEYThe choke knob opens and closes

Seite 9

15CONTROL & FEATURESStarter GripSTARTER GRIPDirectiontopullPulling the starter grip operatesthe recoil starter to crank theengine for starting.Do

Seite 10 - GENERATOR SAFETY

16CONTROL & FEATURESOutput SwitchOUTPUT SWITCHThe output switch has two functions.Following the forced outputprocedure, the generator willprovide

Seite 11

17CONTROL & FEATURESFEATURESGround TerminalDC Output CouplerVoltmeterEco-Throttle SystemDC OUTPUT COUPLERPositivesideNegativesideThe ground termin

Seite 12

−−The information and specifications included in this publication were ineffect at the time of approval for printing. Honda Motor Co., Ltd.reserves th

Seite 13 - CONTROLS & FEATURES

18CONTROL & FEATURESOutput IndicatorOverload IndicatorOUTPUT INDICATOR(GREEN)OVERLOAD INDICATOR(RED)The output indicator (green) is illuminated wh

Seite 14 - CONTROL & FEATURES

19CONTROL & FEATURESFuel GaugeOil AlertIndicatorFULLEMPTYFUEL TANK CAPFUEL GAUGEOIL ALERTINDICATORThe fuel gauge is a mechanical device that measu

Seite 15

20BEFORE OPERATIONARE YOU READY TO GET STARTED?KnowledgeIS YOUR GENERATOR READY TO GO?Your safety is your responsibility. A little time spent in prepa

Seite 16

21BEFORE OPERATIONCheck the EngineCheck the oil level (see page ). A low oil level will cause the Oil Alertsystem to shut down the engine.Check the ai

Seite 17

22SAFE OPERATING PRECAUTIONSOPERATIONBefore operating the generator for the first time, please review theGENERATOR SAFETYsection and the chapter title

Seite 18

23OPERATIONSTARTING THE ENGINE/DC OPERATIONDC OUTPUT COUPLERPOWER CORD COUPLERDC VOLTAGE SELECTOR SWITCHVOLTMETERMAINTENANCE COVERNo gapSelect the sam

Seite 19

24OPERATIONFUEL VALVE LEVEROONNCHOKE KNOBCLOSEDOOPPEENNOOFFFFTurn the fuel valve lever to theON position.Leave the choke knob in theOPEN position to r

Seite 20

25OPERATIONENGINE SWITCHOOFFFFOONNSTARTER GRIPCHOKE KNOBOPENDirectiontopullTurn the engine switch to theON position.When the engine starts, DC output

Seite 21

−−−26OPERATIONForced OutputThe forced output function should only be used by personnel who areknowledgeable regarding UPS battery string operation. Fo

Seite 22 - BEFORE OPERATION

27OPERATIONOUTPUT SWITCHOperation:Verify that the overload indicator (red) is flashing.Press the output switch for 5 seconds, the overload indicator (

Seite 23

1INTRODUCTIONWe want to help you get the best results from your new generator andto operate it safely. This manual contains all the information on how

Seite 24 - OPERATION

28OPERATIONSTOPPING THE ENGINEOONNOOFFFFOUTPUT SWITCHENGINE SWITCHTo stop the engine in an emergency, simply turn the engine switch tothe OFF position

Seite 25

29OPERATIONFUEL VALVE LEVERDC OUTPUT COUPLERPOWER CORD COUPLEROFFONTurn the fuel valve lever to theOFF position.Remove the power cord coupler from the

Seite 26

30THE IMPORTANCE OF MAINTENANCEMaintenance, replacement, or repair of the emission control devicesand systems may be performed by any engine repair es

Seite 27

−−−31SERVICING YOUR GENERATORMAINTENANCE SAFETYSafety PrecautionsCarbon monoxide poisoning from engine exhaust.Burns from hot parts.Injury from moving

Seite 28

**32SERVICING YOUR GENERATORMAINTENANCE SCHEDULEREGULAR SERVICE PERIOD (3)ITEM EachusePerform at every indicated month oroperating hour interval, whic

Seite 29

33SERVICING YOUR GENERATORREFUELINGWith the engine stopped, check the fuel level gauge. Refill the tank ifthe fuel level is low. Refuel carefully to a

Seite 30

34SERVICING YOUR GENERATORFUEL RECOMMENDATIONSFUEL TANK CAPEMPTYTETHERFUEL STRAINERUPPER LEVELMARK (RED)FULLUPPER LEVELMARKFUEL LEVEL GAUGEAfter refue

Seite 31

35SERVICING YOUR GENERATORENGINE OIL LEVEL CHECKDIPSTICKOIL FILLER CAPUPPER LIMITOIL MAINTENANCE COVERCheck the engine oil level with the generator on

Seite 32 - SERVICING YOUR GENERATOR

36SERVICING YOUR GENERATORENGINE OIL CHANGEOIL FILLER CAPUPPER LIMITOIL DRAIN PLUGOIL MAINTENANCECOVERDIPSTICKDrain the oil while the engine is warm t

Seite 33

−37SERVICING YOUR GENERATORENGINE OIL RECOMMENDATIONSAMBIENT TEMPERATUREOil is a major factor affecting performance and service life. Use4-stroke auto

Seite 34

−−−−−−2A FEW WORDS ABOUT SAFETYSafety LabelsSafety MessagesSafety HeadingsSafety SectionInstructionsYour safety and the safety of others are very impo

Seite 35

38SERVICING YOUR GENERATORAIR CLEANER SERVICEAIR CLEANERCOVERCLIPSFOAM AIR FILTERAIR CLEANER COVERCLIPSMANTENANCE COVEROpen the maintenance cover.Rein

Seite 36

39SERVICING YOUR GENERATORAIR CLEANER COVERPAPER AIR FILTERPaper air filter:If the paper air filter is dirty,replace it with a new one. Donot clean th

Seite 37

40SERVICING YOUR GENERATORFOAM AIR FILTER CLEANINGFOAM AIR FILTERA dirty foam air filter will restrict air flow to the carburetor, reducingengine perf

Seite 38

41SERVICING YOUR GENERATORSEDIMENT CUP CLEANINGBREATHER HOSEAIR CLEANER BASE6mmBOLT6 mm NUTSTurn the fuel valve lever to the OFF position.Remove the a

Seite 39

42SERVICING YOUR GENERATORSEDIMENT CUPSEDIMENT CUPO-RING(replace)FILTERGasoline is highly flammable andexplosive.You can be burned or seriouslyinjured

Seite 40

43SERVICING YOUR GENERATORRecommended spark plugs:SPARK PLUG SERVICESPARK PLUGINSPECTION COVERCOVER SCREWSPARK PLUG WRENCHBPR5ES (NGK)W16EPR-U (DENSO)

Seite 41

−−−−−44SERVICING YOUR GENERATORSEALING WASHER0.028 0.031 in(0.7 0.8 mm)Inspect the spark plug. Replaceit if the electrodes are worn or ifthe insulator

Seite 42

45SERVICING YOUR GENERATORSPARK ARRESTER SERVICE6mmBOLTSREAR COVER6 mm CAP NUTSREAR HANDLE6mmBOLTS8mmBOLTSUPPER MUFFLERPROTECTORREAR UNDER PLATEWASHER

Seite 43

46SERVICING YOUR GENERATOR5mmBOLTSEXHAUST TAIL PIPESPARK ARRESTERUse a brush to remove carbon deposits from the spark arresterscreen.Remove the three

Seite 44

47SERVICING YOUR GENERATORLOWER MUFFLER PROTECTORHOOKLOWERMUFFLERPROTECTORREAR COVEROIL FILLER NECKREAR HANDLERUBBER DRIPGUARDOIL DRAIN NECKREAR UNDER

Seite 45

3CONTENTS...GENERATOR SAFETY .6...

Seite 46

48STORAGESTORAGE PREPARATIONCleaningFuelProper storage preparation is essential for keeping your generatortrouble-free and looking good. The following

Seite 47

49STORAGEAdding a Gasoline Stabilizer to Extend Fuel Storage LifeWhen adding a gasoline stabilizer, fill the fuel tank with fresh gasoline.If only par

Seite 48

−−50STORAGEDraining the Fuel Tank and CarburetorDRAIN SCREWGasoline is highly flammable andexplosive.You can be burned or seriouslyinjured when handli

Seite 49

−51STORAGEEngine PreparationChange the engine oil (see page ).Pour a tablespoon (5 10 cc) of clean engine oil into the cylinder.Remove the spark plug

Seite 50

52STORAGESTORAGE PRECAUTIONSREMOVAL FROM STORAGEIf your generator will be stored with gasoline in the fuel tank andcarburetor, it is important to redu

Seite 51

53TRANSPORTINGIf the generator has been running, allow the engine to cool for at least15 minutes before loading the generator on the transport vehicle

Seite 52 - DRAIN SCREW

54ENGINE PROBLEMSEngine Will NotStartPossible Cause CorrectionTAKING CARE OF UNEXPECTED PROBLEMSCheck controlpositions.Check fuel.Check engine oilleve

Seite 53

55TAKING CARE OF UNEXPECTED PROBLEMSEngine LacksPowerCorrectionPossible CauseAir filter clogged.Bad fuel; generatorstored withouttreating ordraining g

Seite 54

56TAKING CARE OF UNEXPECTED PROBLEMSGENERATOR PROBLEMSPossible Cause CorrectionNo Power at theDC Output CouplerOutput indicator isOFF, and overloadind

Seite 55 - TRANSPORTING

−57TAKING CARE OF UNEXPECTED PROBLEMSPossible Cause CorrectionForced OutputFunction CannotBe UsedOverload indicatoris OFF.The UPS batteryvoltage is no

Seite 56

4CONTENTS...OPERATION .22...

Seite 57

58TECHNICAL INFORMATIONSerial Number LocationTECHNICAL & CONSUMER INFORMATIONFRAME SERIAL NUMBERFrame serial number:Date purchased:Record the fram

Seite 58

59TECHNICAL & CONSUMER INFORMATIONCarburetor Modification for High Altitude OperationAt high altitude, the standard carburetor air-fuel mixture wi

Seite 59

60TECHNICAL & CONSUMER INFORMATIONEmission Control System InformationSource of EmissionsTampering and AlteringThe U.S. and California Clean Air Ac

Seite 60 - FRAME SERIAL NUMBER

61TECHNICAL & CONSUMER INFORMATIONProblems That May Affect EmissionsReplacement PartsMaintenanceIf you are aware of any of the following symptoms,

Seite 61

−−−62TECHNICAL & CONSUMER INFORMATIONAir IndexAn Air Index Information label is applied to engines certified to anemission durability time period

Seite 62 - Tampering and Altering

×××−−±±−−63TECHNICAL & CONSUMER INFORMATIONSpecificationsDimensionsEngineGeneratorTuneup SpecificationsITEM SPECIFICATION MAINTENANCEDCX3000ModelD

Seite 63 - MAINTENANCE SCHEDULE

±±××−−−−64TECHNICAL & CONSUMER INFORMATIONSPECIFICATIONTuneup SpecificationsITEM MAINTENANCEDimensionsEngineGeneratorSpecificationsSpecifications

Seite 64

65TECHNICAL & CONSUMER INFORMATIONWiring Diagram04/10/12 11:56:15 31ZS9700_066

Seite 65 - Specifications

66TECHNICAL & CONSUMER INFORMATIONCONSUMER INFORMATIONShop ManualParts CatalogPublicationsThis manual covers complete maintenance and overhaul pro

Seite 66

67INDEXABCD...BEFORE OPERATION .20...

Seite 67 - Wiring Diagram

5CONTENTS...STORAGE .48...

Seite 68

68INDEXEFG...GENERATOR PROBLEMS .56...

Seite 69

69INDEXIKMOQRP...Knowledge .20...

Seite 70

70INDEXSTWV...TAKING CARE OF UNEXPECTED PROBLEMS .54...TECHNICAL

Seite 71

71INDEXSTWV...Voltmeter .17...

Seite 72

72MEMO04/10/12 11:56:58 31ZS9700_073

Seite 73

−−QUICK REFERENCE INFORMATIONUnleaded gasoline with a pumpoctane rating of 86 or higherFuelSpark PlugMaintenanceTypeTypeSubsequentCheck engine oil lev

Seite 75 - QUICK REFERENCE INFORMATION

6GENERATOR SAFETYIMPORTANT SAFETY INFORMATIONCarbon Monoxide HazardsOperator ResponsibilityThis generator is designed for use with CATV/Telecommunicat

Seite 76

−−−7GENERATOR SAFETYElectric Shock HazardsFire and Burn HazardsThe generator produces enough electric power to cause a seriousshock or electrocution i