2.10 AC Output Connection
Photo 2.10.a
Cut “stinger” to a
length of 1.25”
Photo 2.10.c
Insert center conductor into VSF
Connector and tighten
Procedure: Photos 2.10.a, 2.10.b, 2.10.c
1. Prepare the incoming coaxial cable used for the distribution of power
(including external fittings not supplied by Alpha).
2. Loosen the APC’s (APL) brass seizure screw output fitting to accommodate
the center pin (“stinger”) of the cable connector. (See Photo 2.10.b).
3. Screw the cable connector into the output port (large hex nut fitting) located
on the baseplate of the APC (APL), (Photo 2.10.c). Make sure that the
center pin extends far enough into the fitting so that the seizure assembly
can be secured. NOTE: The center conductor may also be trimmed to allow
for a flush fit, the length of the center conductor should be 1.25” from the
end to the center of the O-Ring. (See Photo 2.10.a).
4. Tighten the brass seizure screw on the cable “stinger” or center conductor.
If a connection is left loose, arcing could result and possible damage to the
center conductor could occur. During routine maintenance, always check
the seizure screw assembly to ensure that it is tight. (Photo 2.10.b).
2. INSTALLATION
25
1.25”
Hex-nut Fitting
(VSF Connector)
Photo 2.10.b
Seizure screw
Loosen seizure screw to
accommodate center
conductor “stinger” from
adaptor