2.11 Options
2. INSTALLATION
26
APC and APL Series non-standby power supply are designed so that options can be
installed easily in the field in a minimum amount of time.
NOTES: Options specified at the time of ordering will be installed by the factory.
Options ordered at a later time must be installed only by qualified service personnel.
Only the SIL-C; LA-L; and GLK options can be used with the APL model non-
standby power supply.
CAUTION: POWER SHOULD ALWAYS BE REMOVED BY UNPLUGGING THE
UNIT’S POWER CORD BEFORE INSTALLING OPTIONS.
2.11.1 SIL-C (Status Indicator LED) Photo 2.11.1
The Status Indicator LED indicates AC output from the power supply during LINE
operation.
Procedure:
1. Before installing the SIL-C, you will first need to remove the knockout plug
from the base of the enclosure. This can be pried out using a large flat-
blade screwdriver.
2. Route the connector-end of the SIL-C option up through the knockout hole
and into the base of the enclosure.
3. Route the large star-washer and nut over the connector and wires of the
SIL-C. Screw the nut onto the threaded portion of the lamp’s base and
tighten.
4. Connect the small 2-pin connector into its mating connector located in the
enclosure base.
5. Apply power and test the lamp for proper operation.
Connections from
baseplate to SIL-C (small
2-pin connector)
SIL-C installed in
baseplate
Photo 2.11.1
SIL-C Installation